-
GDSF-311WP SF6 Dew Point and Purity Tester
GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company.
-
GDSF-411CPD SF6 Gas Comprehensive Analyzer
GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product.
-
GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.
-
GDWS-311RC SF6 Gas Dew Point Tester
GDWS-311RC is ideal instrument when it is necessary to test water content of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument
-
GDSF-311WPD 3-In-1 SF6 Gas Analyzer
GDSF-311WPD (GDSF-411WPD) is an ideal instrument when it is necessary to test water content, purity and decomposition products of SF6 gas. The core component of dew point test is DRYCAP® series sensors produced by Finland Vaisala company.
-
GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.
-
GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions.
The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point.
Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation.
GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device.
-
GDFJ-311M SF6 Gas Decomposition Product Tester
GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product.
-
GDP-311MIX SF6/N2 Mixed Gas Purity Analyzer
The GDP-311MIX SF6/N2 mixed gas purity analyzer integrates SF6 purity testing and O2 testing. With one on-site measurement, all indicators can be tested, greatly saving gas in the equipment, reducing user workload, and improving work efficiency.
The GDP-311MIX SF6/N2 mixed gas purity analyzer adopts the best sensors; The purity of SF6 gas adopts a stable and reliable German Smart Gas NDIR principle sensor, and oxygen testing uses a British CITY electrochemical sensor. Color LCD display, real-time display of various parameters, foolproof operation throughout the process, built-in rechargeable battery, dual-use for AC and DC.
-
GDP-311IR SF6 Gas Purity Tester (IR Method)
GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company.
-
GDSF-411WPD 3-in-1 SF6 Gas Analyzer(with pump)
GDSF-411WPD 3-in-1 SF6 Gas Analyzer is combined of SF6 humidity (dew point) test, SF6 purity test and SF6 gas decomposition product test. It integrates the functions that can only be achieved with three instruments in one instrument. One-time on-site measurement can complete the detection of all indexes, which greatly saves the gas in the equipment, at the same time reduces the workload of users and improves work efficiency.
-
GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content.